CHFIRE 200X pressure reducing valve is easy to maintain and has high pressure control accuracy. It is a functional valve that uses the medium's own energy to adjust and control pipeline pressure.
CHFIRE 200X Pressure reducing valves from China designed to reduce a higher unregulated inlet pressure to a constant, reduced downstream (outlet) pressure regardless of variations in demand and/or upstream (inlet) water pressure.
CHFIRE 200X pressure reducing valve is easy to maintain and has high pressure control accuracy. It is a functional valve that uses the medium's own energy to adjust and control pipeline pressure.
CHFIRE 200X pressure reducing valve is a valve used to adjust the water supply direction in a water supply system where fire water and domestic water are connected in parallel.
CHFIRE 200X pressure reducing valve flange is an important component used in various industries such as oil and gas, chemical, and water treatment. It works by reducing the high pressure of the fluid flowing through the pipeline to a lower pressure level that is suitable for the downstream applications.
The pressure-reducing valve is adjusted to reduce the inlet pressure to a desired outlet pressure and rely on the energy of the medium itself to keep the outlet pressure automatically stable. From fluid mechanics point of view, pressure reducing valve is a throttling element, local resistance to change that by changing the throttling area, change the kinetic energy of the flow velocity and fluid, different pressure loss, so as to achieve the goal of decompression. Then the control and adjustment system can be adjusted to balance the pressure fluctuation of the valve and the spring force, so that the pressure of the valve remains constant within a certain margin of error. It is widely used in high rise buildings, water pressure of the city water supply pipe, and other occasions, so as to ensure the proper service water pressure and flow of water points in the water supply system.
CHFIRE 200X pressure reducing valve is a valve used to adjust the water supply direction in a water supply system where fire water and domestic water are connected in parallel.
The pressure reducing valve utilizes the pilot valve for self-control, does not require other devices and energy, is easy to maintain, has high pressure control accuracy, is less affected by inlet pressure and flow, and has reliable pressure reduction and stabilization.
The pressure reducing valve utilizes the pilot valve for self-control, does not require other devices and energy, is easy to maintain, has high pressure control accuracy, is less affected by inlet pressure and flow, and has reliable pressure reduction and stabilization.
200X pressure reducing and stabilizing valve consists of main valve, pilot valve, needle valve, ball valve, micro filter and pressure gauge to form hydraulic control takeover system. When in use, after the outlet pressure is adjusted, it can automatically maintain a stable outlet pressure.
200X pressure reducing valve is a valve used to adjust the water supply direction in a water supply system where fire water and domestic water are connected in parallel. When a fire occurs, the firefighting department urgently needs a large amount of water, and the domestic water supply is immediately cut off to ensure sufficient water for firefighting; when the firefighting stops using water and the pressure decreases, the valve automatically opens and is in a normally open state to restore the domestic water supply. This valve eliminates the need for a separate firefighting water supply network, greatly saving construction costs and water consumption. The valve has high control sensitivity, is safe and reliable, is easy to debug, and has a long service life.
Flanged globe type pressure relief valve (Fire pump relief valve) is used in the discharge of fire pump with flanged connection. It automatically relieves excessive pressure, so to maintain constant pressure. It allows the fire pump to be stopped without causing surging.
A Pressure Relief Valve is defined by NFPA 20 (3.3. 67.5 Relief Valve) as “A device that allows the diversion of liquid to limit excess pressure in a system.” In general, a PRV is a safety device, designed to protect a pressurized system during an overpressured event.
The pressure relief valve (500X) is a hydraulic control valve, mainly used in fire protection or other water supply systems to prevent system overpressure and maintain the pressure of the fire water supply system. When the pressure in the water supply pipeline exceeds the set pressure of the pressure relief valve, the pressure relief valve will release the pressure in time to protect the safety of the pipeline.
A filter must be installed before the 500X pressure relief valve and the pressure holding valve. When adjusting, the screw on the pilot valve should be withdrawn, the water pump should be started to discharge from the pressure relief valve, and the adjusting screw should be gradually screwed in to gradually increase the pressure until the required set pressure is reached. Tighten the nut after adjustment.
500X pressure relief valve is a device used in water supply pipe network systems and urban water supply projects in high-rise buildings and living areas. The device consists of a main valve, pilot valve, needle valve, ball valve, micro filter and pressure gauge to form a hydraulic control takeover system. It uses hydraulic automatic operation and can be used as a pressure relief valve or a pressure holding valve.
The 500X pressure relief/pressure holding valve consists of a main valve, a pressure relief/pressure holding pilot needle valve, a ball valve, a micro filter and a pressure gauge to form a hydraulic control takeover system. It can be used as a pressure relief valve or a pressure holding valve by hydraulic automatic operation. When used as a pressure relief valve, it can maintain the water supply line pressure below the set safety value; when used as a pressure holding valve, it can maintain the upstream water pressure of the main valve above the set value and maintain the upstream water supply pressure of the main valve.
500X pressure relief and pressure sustaining valve is mainly used to adjust the medium flow, pressure, temperature, liquid level and other process parameters in the field of industrial automation process control. According to the control signal in the automation system, the valve opening is automatically adjusted to achieve the adjustment of medium flow, pressure, temperature and liquid level.
A Pressure Reducing Valve (PRV) is an Automatic Control Valve designed to reduce a higher unregulated inlet pressure to a constant, reduced downstream (outlet) pressure regardless of variations in demand and/or upstream (inlet) water pressure.
Rising stem soft-sealed gate valve is an industrial valve. The opening and closing part of the soft-sealed gate valve is the gate. The movement direction of the gate is perpendicular to the direction of the fluid. The gate valve can only be fully opened and fully closed, and cannot be adjusted or throttled.
Rising stem soft-sealed gate valve is an industrial valve. The opening and closing part of the soft-sealed gate valve is the gate. The movement direction of the gate is perpendicular to the direction of the fluid. The gate valve can only be fully opened and fully closed, and cannot be adjusted or throttled.
Zone Control Valve is a system designed to separate the area in case of maintenance and to get the indication of fire zone on a combination of Butterfly valve, Flow Switch, Pressure Gauge and Test & Drain Valves.
CH40-63 butterfly valve for fire fighting system
Place of Origin: China Brand Name: CHFIRE Model Number:CH43-02 Product name:Big nose landing valve Material: Brass Size: 2.5'' DN65 Inlet: 2.5'' thread or 2.5'' flange Type: thread pressure regulating valve Application: fire fighting equipment Pressure: 0.8MPa-1.6MPa Outlet: 2.5''INST to BS336 Pressure rating: lower pressure Color: Natural Brass