This industrial firefighting foam system features a 1,000-liter vertical carbon steel bladder tank with a design pressure of 12.1 bar and a test pressure of ≥17.3 bar; it supports standard foam mixing ratios of 3% and 6% and is compatible with mainstream foam concentrates such as AFFF and alcohol-resistant types.
The foam system 1000–5000 liter fixed horizontal foam bladder tank for firefighting features a horizontal carbon steel pressure vessel design with an internal oil-resistant rubber bladder. With a capacity range of 1,000 to 5,000 liters, it offers superior stability compared to vertical tanks of the same capacity and is suitable for large-scale foam fire suppression systems.
CHFIRE foam bladder tank for foam spray systems serves as the core liquid supply unit for foam sprinkler fire suppression systems; it connects directly to closed or open foam spray piping networks and delivers a compliant foam-water solution steadily without the need for an external power source.
Serving as a core component of industrial foam fire suppression systems, the firefighting pressure foam bladder tank operates without external power; it utilizes water pressure to compress an internal bladder, precisely discharging a foam solution at a 3% or 6% mixing ratio, making it suitable for extinguishing Class B flammable liquid fires.
The 1,000L vertical fire foam bladder tank features a carbon steel vessel with an internal oil-resistant rubber bladder; it has an operating pressure of 0.6–1.2 MPa, a design pressure of 12.1 bar, and a test pressure of ≥17.3 bar.
3000L vertical foam bladder tank: 3000L capacity, vertical structure; the tank body is typically made of carbon steel; operating pressure: 0.6–1.2 MPa.
The foam bladder tank features a carbon steel pressure vessel design with a rated working pressure of 0.6–1.2 MPa and a design pressure of at least 1.5 times the working pressure; it can be upgraded to stainless steel construction to suit highly corrosive environments.
The fire foam bladder tank is a core component of the balanced-pressure proportioning system; it consists of a carbon steel pressure vessel and a flexible separation bladder, enabling it to stably maintain a 3% or 6% mixing ratio of water to foam concentrate under conditions of varying flow rates and pressures.
The foam bladder tank utilizes a bladder to physically separate the water from the foam concentrate throughout the process; unused concentrate is not diluted by the water and can be retained for future use.
The foam bladder tank is the core component of a fixed foam fire suppression system; it delivers a compliant foam-water mixture reliably without requiring an external power source, making it suitable for Class B fire protection in settings such as oil depots and chemical plants.
The CHFIRE bladder foam tank is constructed from corrosion-resistant carbon steel or stainless steel, with both internal and external surfaces treated with an epoxy zinc-rich anti-corrosion coating. It features an internal bladder made of oil- and corrosion-resistant nylon-reinforced nitrile rubber, capable of withstanding corrosive attack in chemical environments and coastal areas with high salt-spray exposure.
CHFIRE bladder foam tanks offer standard capacities ranging from 200L to 10,000L and an operating pressure of 0.6–1.2 MPa; they support mixing ratios of 3% or 6% and are available in both vertical and horizontal installation configurations.
CHFIRE 1000L bladder foam tank with an operating pressure of 0.6–1.6 MPa and a proportioning ratio of 3% or 6%. The tank is constructed from carbon steel as standard, with 304 stainless steel available as a custom option; it is available in both vertical and horizontal mounting configurations.
Foam bladder tank is a carbon steel pressure vessel fitted with the internal nitrile/EPDM rubber bladder.Pressurized fire water enters the interlayer between the tank shell and the bladder. Squeezes the bladder to discharge foam cercentrate.
Fire baldder foam tank for balanced pressure foam proportion fire system, matched with foam proportioner and foam monitor.
CHFIRE 500L vertical fire foam bladder tank is a carbon steel pressure vessel,a core component of balanced pressure foam proportioning system.
Bladder Foam Tank (Foam Bladder Tank) is the core equipment of balanced-pressure foam proportion fire suppression system, widely matched with foam proportioner, foam monitor, foam sprinkler and low/medium expansion foam generators for Class B flammable liquid fire protection.
Bladder foam tank is a fire foam storage device with internal rubber bladder,separating foam liquid and water pressure medium,widely used in fire extinguishering systems for oil depots,chemical plants,docks,shopping malls.
Fire hose cabinet is a durable fire safety cabinet made of carbon steel or stainless steel. With optional bottom support feet, it stays dry even in damp or outdoor areas. Its clear marked, easy-open door lets you get firefighting tools in seconds. It fits commercial, industrial and public sites, fully compliant with standard fire safety rules.
The fire department connection is a critical facility in building fire protection systems, which allows firefighters to connect external fire pumps to pressurize and replenish water for the building's indoor sprinkler systems and fire hydrant networks.
CHFIRE external fire department connection for building dry riser system. Used for fire truck water supplement. Equipped with check valve to prevent backflow, ensures stable pressure and fast emergency water supply for high-rise fire fighting.
CHFIRE 4 way breeching inlet serves as dry riser inlet,connecting fire trucks to building dry riser pipeline for emergency water supply in fires.
CHFIRE 4-way breeching inlet is connected fire trucks to building internal fire piping to supplyment fire water when internal water supply fails.
4-way breeching inlet supplies high pressure fire water from fire trucks to building pipe networks. Ductile iron body with four ports and dustproof caps for large commerical premieses.
Two way breeching inlet,also known as double breeching inlet,is a fixed fire water supply fitting installed on building exterior wall.It connects fire engine hoses to indoor fire pipe network,supplementing water pressure and flow for indoor sprinkler&hydrant systems during fire emergencies.
Two way breeching inlet is fire service connection equipment, used to connect fire pump truck pipeline with building internal fire pipe network, two outlets design for simultaneous water supply.
Fire water divider is core portable fire fighting accessory, designed to split single main water supply into multiple independent branch water lines for simultaneous multi-point fire suppression.
This mobile foam unit serves as supporting equipment for stationary foam fire system. Easy to connect and supply foam liquid during fire emergencies.
200L mobile foam unit with hand push wheels for easy movement. Fast assembled for emergency foam fire extinguishment, widely used in industrial workshops, warehouses and parking areas.
Hand-push wheeled construction for convenient relocation and rapid firefighting setup.Ideal for factory, warehouse and commercial premises fire protection.
This mobile foam trolley is engineered for emergency fire rescue.Hand-push wheeled design enables flexible movement and fast on-site deployment.Widely applied in warehouses, factories and parking lots for efficient foam fire suppression.
Mobile foam trolley unit is movable fire device for oil fire fighting, convenient to transport and quick for emergency fire control.